{"id":12,"date":"2023-10-25T05:51:12","date_gmt":"2023-10-25T05:51:12","guid":{"rendered":"https:\/\/diagenbioinno.com\/?page_id=12"},"modified":"2023-10-26T08:33:06","modified_gmt":"2023-10-26T08:33:06","slug":"%e7%94%a2%e5%93%81","status":"publish","type":"page","link":"https:\/\/diagenbioinno.com\/?page_id=12","title":{"rendered":"Products"},"content":{"rendered":"\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<p class=\"has-background\" style=\"background-color:#c7fcc0bd;font-size:clamp(1.039rem, 1.039rem + ((1vw - 0.2rem) * 1.02), 1.6rem);\"><strong>Rapid Accurate Portable Tests (RAPT) Point-of-Care Testing<strong> (PO<\/strong>CT) Reader<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-video alignwide\"><video height=\"1080\" style=\"aspect-ratio: 1920 \/ 1080;\" width=\"1920\" controls src=\"https:\/\/diagenbioinno.com\/wp-content\/uploads\/2023\/10\/Diagen\u6a5f\u53f0\u6280\u8853\u5f71\u7247.mp4\"><\/video><\/figure>\n\n\n\n<p class=\"has-text-align-center has-background\" style=\"background-color:#f5f5f5ed;font-size:clamp(1.146rem, 1.146rem + ((1vw - 0.2rem) * 1.189), 1.8rem);\"><strong><em>RAPT focuses on your lifelong health<\/em><\/strong><\/p>\n\n\n\n<div class=\"wp-block-group has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"background-color:#abb7c238;font-size:clamp(1.25rem, 1.25rem + ((1vw - 0.2rem) * 1.364), 2rem);\">\n<p style=\"font-size:clamp(0.984rem, 0.984rem + ((1vw - 0.2rem) * 0.938), 1.5rem);\"><strong>Product Features<\/strong>: <\/p>\n\n\n\n<ul class=\"wp-block-list\" style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">\n<li>High stability and accuracy<sup data-fn=\"5d115348-8deb-4be5-8ea6-5acb30592fde\" class=\"fn\"><a href=\"#5d115348-8deb-4be5-8ea6-5acb30592fde\" id=\"5d115348-8deb-4be5-8ea6-5acb30592fde-link\">1<\/a><\/sup><\/li>\n\n\n\n<li>Short testing time<\/li>\n\n\n\n<li>Easy-to-use color touch screen<\/li>\n\n\n\n<li>Lightweight and portable<\/li>\n\n\n\n<li>Less stringent storage requirements<\/li>\n\n\n\n<li>High capture efficiency of pathogenic nucleic acids<\/li>\n\n\n\n<li>Easy to insert PCR chip<\/li>\n\n\n\n<li>Small temperature differences in the process (&lt;2%)<\/li>\n\n\n\n<li>Small Ct value error compared with ABI<sup data-fn=\"a4a18d46-da86-4e96-87d5-5a320a116dde\" class=\"fn\"><a href=\"#a4a18d46-da86-4e96-87d5-5a320a116dde\" id=\"a4a18d46-da86-4e96-87d5-5a320a116dde-link\">2<\/a><\/sup> control group in clinical trials (&lt;1.5%)<\/li>\n<\/ul>\n<\/div>\n\n\n<ol class=\"wp-block-footnotes\"><li id=\"5d115348-8deb-4be5-8ea6-5acb30592fde\">Care must be taken to avoid collisions of the reader that can cause the displacement of optical monitoring to prevent from obtaining inaccurate Ct values. <a href=\"#5d115348-8deb-4be5-8ea6-5acb30592fde-link\" aria-label=\"\u8fd4\u56de\u8a3b\u8173\u53c3\u7167 1\">\u21a9\ufe0e<\/a><\/li><li id=\"a4a18d46-da86-4e96-87d5-5a320a116dde\">Applied Biosystems StepOne\u2122 Real-time PCR System <a href=\"#a4a18d46-da86-4e96-87d5-5a320a116dde-link\" aria-label=\"\u8fd4\u56de\u8a3b\u8173\u53c3\u7167 2\">\u21a9\ufe0e<\/a><\/li><\/ol>\n\n\n<div class=\"wp-block-group has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"background-color:#abb7c238;font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">\n<p style=\"font-size:clamp(0.984rem, 0.984rem + ((1vw - 0.2rem) * 0.938), 1.5rem);\"><strong>Clinical Benefits\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Early outbreak control<\/li>\n\n\n\n<li>Rapid separation of infected patients for next step treatment<\/li>\n\n\n\n<li>Easy sample preparation<\/li>\n\n\n\n<li>Shortened detection time; improve the testing rate of the public<\/li>\n\n\n\n<li>Reduced costs and healthcare resources<\/li>\n\n\n\n<li>Reduce the pressure on the central laboratory; decreased workflow of healthcare workers<\/li>\n\n\n\n<li>Benefited healthcare workers, patients, and hospitals\/clinics\/ pharmacies<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"background-color:#abb7c238;font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">\n<p style=\"font-size:clamp(0.984rem, 0.984rem + ((1vw - 0.2rem) * 0.938), 1.5rem);\"><strong style=\"white-space: normal;\">Product Specifications\uff1a<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Storage Temperature<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">15-30 <sup>o<\/sup>C<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Sample Type<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Saliva<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Sample Prep Time<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">&lt; 1 min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Sample Number<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Medical Device Classification<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Chip\uff1aClass 2<br>Analyzer\uff1aClass 1<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Weight<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Chip\uff1a0.05 kg<br>Analyzer\uff1a1.5 kg<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Dimensions<br>(W x D x H)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Chip\uff1a10 cm x 5 cm x 1 cm<br>Analyzer\uff1a34 cm x 25 cm x 15 cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Detection Time<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">20 min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Limit of Detection (LoD)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0.05 ng\/mL<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Power<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">12 V DC\/6.0 A<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<p class=\"has-background\" style=\"background-color:#c7fcc0bd;font-size:clamp(1.039rem, 1.039rem + ((1vw - 0.2rem) * 1.02), 1.6rem);\"><strong>Rapid Accurate Portable Tests (RAPT) SARS-CoV-2 Nucleic Acid Test Kit<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"background-color:#abb7c23d;font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">\n<p class=\"has-background\" style=\"background-color:#abb7c200;font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">Coronavirus disease 2019 (COVID-19) is a respiratory illness caused by a novel human coronavirus, named SARS-CoV-2 (severe acute respiratory syndrome coronavirus-2) by the World Health Organization.&nbsp;COVID-19 and influenza are potentially fatal infections that result in significant worldwide morbidity and mortality. Rapid and accurate diagnosis of SARS-CoV-2 infections is important in individuals suspected of a respiratory infection.&nbsp;Using the <strong>RAPT <strong>SARS-CoV-2<\/strong><\/strong> <strong>Nucleic Acid Test Kit<\/strong> to detect the SARS-CoV-2 virus can help to inform time-critical medical decision-making, facilitate infection control efforts, promote efficient resourcing, optimize use of targeted therapies and antimicrobials, and reduce ancillary testing or procedures. <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-base-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">\n<p class=\"has-background\" style=\"background-color:#abb7c238;font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">The <strong>RAPT SARS-CoV-2 Nucleic acid Test Kit<\/strong> is a rapid, single-use molecular diagnostic test kit for use on the RAPT system with an automated real-time RT-PCR assay for the qualitative detection of the novel coronavirus SARS-CoV-2 from self-collected saliva samples (under the guidance of medical professional, and\/or healthcare providers) in individuals with known or suspected COVID-19 (Coronavirus Disease-2019). <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"background-color:#abb7c23d;flex-basis:100%\">\n<p style=\"font-size:clamp(0.984rem, 0.984rem + ((1vw - 0.2rem) * 0.938), 1.5rem);\"><strong>RAPT Test Kit&nbsp;consists of: <\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\" style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.591), 1.2rem);\">\n<li>A single-use biochip<\/li>\n\n\n\n<li>Specimen preparation kit<\/li>\n\n\n\n<li>Reagent kit (sample vial, wash buffer vial and elution buffer vial)<\/li>\n\n\n\n<li>Instructions manual<\/li>\n\n\n\n<li>Waste disposal bag<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"background-color:#abb7c23d;flex-basis:100%\">\n<p style=\"font-size:clamp(0.929rem, 0.929rem + ((1vw - 0.2rem) * 0.856), 1.4rem);\"><strong><strong>Sample Preparation Steps\uff1a<\/strong><\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image alignwide size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"523\" src=\"https:\/\/diagenbioinno.com\/wp-content\/uploads\/2023\/10\/\u8a66\u5291\u5957\u7d44\u6982\u5ff5\u5716-1024x523.png\" alt=\"\" class=\"wp-image-227\" srcset=\"https:\/\/diagenbioinno.com\/wp-content\/uploads\/2023\/10\/\u8a66\u5291\u5957\u7d44\u6982\u5ff5\u5716-1024x523.png 1024w, https:\/\/diagenbioinno.com\/wp-content\/uploads\/2023\/10\/\u8a66\u5291\u5957\u7d44\u6982\u5ff5\u5716-300x153.png 300w, https:\/\/diagenbioinno.com\/wp-content\/uploads\/2023\/10\/\u8a66\u5291\u5957\u7d44\u6982\u5ff5\u5716-768x392.png 768w, https:\/\/diagenbioinno.com\/wp-content\/uploads\/2023\/10\/\u8a66\u5291\u5957\u7d44\u6982\u5ff5\u5716.png 1140w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Rapid Accurate Portable Tests (RAPT) Point-of-Care Test [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":"[{\"content\":\"Care must be taken to avoid collisions of the reader that can cause the displacement of optical monitoring to prevent from obtaining inaccurate Ct values.\",\"id\":\"5d115348-8deb-4be5-8ea6-5acb30592fde\"},{\"content\":\"Applied Biosystems StepOne\u2122 Real-time PCR System\",\"id\":\"a4a18d46-da86-4e96-87d5-5a320a116dde\"}]"},"class_list":["post-12","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=\/wp\/v2\/pages\/12","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=12"}],"version-history":[{"count":13,"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=\/wp\/v2\/pages\/12\/revisions"}],"predecessor-version":[{"id":242,"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=\/wp\/v2\/pages\/12\/revisions\/242"}],"wp:attachment":[{"href":"https:\/\/diagenbioinno.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=12"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}